Frequency plan | 5,6,7,8GHz | 11 GHz | 13 GHz | 15 GHz | 18 GHz | 23 GHz | 26 GHz | |
RF output power on antenna connector, dBm | 4QAM 16/32QAM 64/128QAM |
26/30 24/28 22/26 |
26/31 23/28 21/26 |
24 22 20 |
24 22 20 |
23 21 19 |
22 20 18 |
22 20 18 |
Channel spacing, MHz | 3,5/7/ 14/28 |
14/28 | 3,5/7/14/28 | 13,75/ 27,5 |
3,5/7/14/28 | |||
Frequency stability | ± 5х10-6 | |||||||
Frequency seeting step | 0,25 MHz | |||||||
ATPC output power adjusting range | 20 dB in 1 dB step | |||||||
Receiver treshold at antenna connector in dBm for BERR=10-6 |
modulation/BW 4QAM 16QAM 32QAM 64QAM 128QAM |
3,5 MHz 7 MHz 14 MHz 28 MHz - -86 -88 -87 -82 -86 -83 -80 -85 -82 -78 -76 - - -74 - - - -72 -69 |
||||||
Link protection modes | Hot Stand-By, Space Diversity, Frequency Diversity, Hitless switch | |||||||
Transmission capacity, given by N x E1 without FEC | modulation/BW 4QAM 16QAM 32QAM 64QAM 128QAM |
3,5 MHz 7 MHz 14 MHz 28 MHz - 4 - 5 7 - 11 15 - 22 4 7 - 8 15 - 18 30 - 39 4 - 5 9 - 11 19 - 24 40 - 50 - - 27 - - - 30 - 36 68 - 72 * In the case of link protection 2U chassis is necessary; * E3: every E3 occupies 17 x N (N is the number of equivalent E1 channels); * Ethernet: transmission capacity is: 2092 kb/s x N (N is the number of equivalent E1 channels) |
||||||
Trafic interface | PDH interface ITU-T recommendations bit rate |
E1 G.703 point 6 2048 kb/s |
E3 G.703 point 8 34368 kb/s |
|||||
Ethernet interface | 10Base-T/100 Base-Tx adaptive; compatibility IEEE 802.3 half duplex and full duplex; IEEE 802.3 management statistics (RMON); IEEE 802.3u auto-negotiation; connector type RJ45, Automatic connection MDI/MDIX; number of interfaces on central module 2. |
|||||||
E1 wayside channel | ITU-T recommendations bit rate (plesiochronous) multiplexing principle |
G.703 point 6 2.048 kb/s RSOH and MSOH bytes |
||||||
Other interface | management interface service channel interface |
10Base-T / 100Base-Tx адаптируемый; 10Base-T / 100Base-Tx адаптируемый; |
||||||
Mechanical / Environmental | operation climatic conditions (temp./humidity.) |
indoor unit (IDU) -5°С...+45°С/8...95% ETSI EN 300 019 class 3.1Е outdoor unit (ODU) -33°С...+50°С/5...100% ETSI EN 300 019 class 4.1Е (-50°С...+50°С option) |
||||||
storage/transport conditions | ETSI EN 300 019 class 1.1 / class 2.3 | |||||||
EMC compatibility | ETSI 301 489-4 | |||||||
power supply | from 20V to 72V ETSI EN 300 132 | |||||||
power consumption IDU power consumption ODU |
<19 W - 1U, <39 W - 2U <25 W |
|||||||
dimensions (H x W x D) IDU dimensions (H x W x D) ODU |
45 х 442 х 240 mm - 1U; 86 x 442 x 240 mm - 2U 200 х 150 х 80 / F305 x 120 |
|||||||
weight IDU weight ODU |
3,17 kg - 1U; 5,96 kg - 2U <6 kg |